Description
• Axial-leaded fast-acting
• 5 x 15mm physical size
• Nickel-plated brass endcap construction
• Optional sleeve is flexible flouropolymer (UL Flammability rating VW-1).
• UL Listed product meets standard UL 248-14
• High breaking capacity for lighting ballast applications
Electrical Characteristics
Rated Current | Amp Rating | Opening Time |
3A | 100% | None |
135% | 60 minutes max. | |
200% | 2 seconds max. |
Agency Information
• UL Listed Card: C517 3A (Guide JDYX, File E19180)
• UL Recognition Card: C517 3A (Guide JDYX2, File E19180)
• CSA Certification Card: 3A (Class 1422-01, File 53787)
Ordering
Specify product code
• Insert packaging code prefix before part number. E.g. BK(or TR2)/C517-3-R
Specify option code, if desired
• For insulation sleeve, insert “S” after part series. E.g. BK/C517S-3-R
Dimensions - (mm)
Drawing Not to Scale
With TR2 packaging code, lead wire length is 20.3mm
Specifications
Part Number | Voltage Rating Vac | Interrupting Rating at Rated Voltage(amp) Vac | Typical DC Cold Resistance* (Ω) | Typical Melting I2t** AC | Typical Voltage Drop (mV)*** |
C517-3A | 350**** | 100A | 0.0345 | 5.87 | 141.7 |
250 | 100A | ||||
125 | 10,000A |
** Typical Melting I2t (A2Sec) (Minimum I2t at 10 times rated current)
***Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
**** 350Vac is UL Recognized
Time-Current Curve
Packaging Code
Packaging Code Prefix | Description |
BK | 100 fuses packed into a cardboard carton |
TR2 | 1,500 fuses packed into tape on a reel (20.3mm lead wire length) |
Option Code
Option Code | Description |
S | Insulation Sleeve |